Day 1
– Classroom (8. 5 hrs)
Lecture
1: Introduction to Line Sweeping
- What is a line
sweep
- Understanding
Return Loss and VSWR
- Impedance and
Impedance Matching
- Understanding
Insertion Loss
Lecture
2: System Components and Performance
- Transmission
Lines
- Connectors
- Calculating Insertion
Loss
- Quality Of installation
- Causes of Impedance
Mismatch
- Transmission
Line Systems
Lecture
3: Line Sweeping Fundamentals
- Understanding
How to Perform Basic Measurements
- Distance to Fault
- Use of Precision
Components (Open/Short/Load)
- Important Setup
Considerations
|
Lab
1: Basic Setup and Measurements (Instructor-led)
- Site Master Functions
and Operations
- Calibration
- Performing Return
Loss/VSWR and Insertion Loss
- Distance to Fault
Setup
Lab 2:
Basic Setup and Measurements (Self-paced)
- Additional Practice
of Basic Measurements
- Recognizing the
Difference Between
- Passing and Failing
Systems
- Using Distance
to Fault to locate Problems
- Review of the
Different Types of Measurements
- Interpretation
of Test Results
Lecture
4: Trace Interpretation
- Review of the
Different Types of Measurements
- Interpretation
of Test Results
|
Day 2
– (Morning) Classroom (4 hrs)
- Downloading Plots
to PC
- Using HHST to
Process and Save Data
Lab 3:
Antenna Characterization
Lab 4:
Additional Troubleshooting and System
Verification
Afternoon Session:
- Hands on Practical
and Written Exams
|